| FEATURES |
| NEMA 4x Non-Metallic Enclosure with LCD display and keypad |
| Automatic re-start after a power interruption |
| No calibrations or frequency adjustments |
| Log of events with time/date stamp and first-out indication |
| P2385 Relay Output Board for NO/NC contacts for use with Programmable Controllers and Central Monitoring Systems |
| P2281
REMOTE PULL SWITCH MODULES |
| One P2281 Module required for each pull cord or stop switch |
| Up to 32 Modules may be monitored on a single belt flight |
| Modules use existing 2-wire stop switch circuitry |
| SPECIFICATIONS |
|
Enclosure Type:
|
UL Listed NEMA 4X
Non-Metallic |
Dimensions: |
17" x 15.5" x 8.5" |
|
Power Input:
|
115 VAC / 24 VDC |
Power Consumption: |
150 mA |
|
Sensors:
|
Pull
Cord Modules |
Input Range: |
Up
to 32 modules |
|
Resolution:
|
12 Bit |
Sensor Outputs: |
Four Open Collector Outputs for Each Sensor |
|
System Outputs:
|
Sensor Fail, Warning, and Alarm |
Relay Contact Ratings: |
10 Amps @ 240 VAC SPDT |
|
Operating Temperature:
|
0 to +40 Degrees C |
Memory: |
64 K for User Input Data |
|
Keypad:
|
High Resolution Soft Touch Membrane |
Display: |
Eight Line Graphic LCD Continuous Read-Out |
|
Trend Display:
|
Historical Graphs of 15 Minutes to 24 Hours |
|
|