Should the battery become discharged and its voltage drops below 90% of its fully charged voltage, the
"BATTERY LOW" LED will be illuminated. The output relay will drop out to prevent further draining of the battery.A 0.5 Amp Fuse is installed to protect the circuit in case of a short circuit in the output power. |
| SPECIFICATIONS | |||
| Power Input: | 110 VAC | Dimensions: | 9½"W x 11"H x 7"D |
| Output Voltage: | 24 VDC | Weight: | 12 lbs. |
| Output Current: | 1.10 A | Sealed Rechargeable Batteries: | 2 |